RACKLIGHTING


The best way to determine the required horizontal and vertical illumination levels is to consider the average to minimum ratios. The horizontal average to minimum ratio for a rack area should not exceed 3:1. If the average light level in an aisle is 200lux, the minimum horizontal levels should be 67 lux or greater. The vertical average to minimum ratio for this same area should not exceed 10:1. This means that if the average lux level is 150, the minimum vertical lux level should never be less than 15 lux.
Why HiRack LED linear high bay is the best light for warehouse with aisles?
Common high bay lighting distribution is a round pattern on the ground. Only 50% of the lumen output are useful for the aisle and racks

But our HiRack linear high bay with long and narrow pattern will not only contribute to lighting lux level but also uniformity.


Model | LED Type | System Efficacy | Luminous Flux | CCT | Beam Ange | CRI | System Efficiency | Power Supply | Input Voltage | Frequency Range | Output Voltage | Output Current | Power Efficiency | Power Factor | Total Harmonic Distortion | System Power Consumption | LED Power Consumption | Fixture Material | Ingress Protection | Luminare Net Weight | Life Span | Junction Temperature(Tj ) | Storage Temperature | Operating Temperature | Operating Humidity | Outlook Dimensions | Export Carton Size |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
90W HIRACK LED LINEAR HIGH BAY | Nichia SMD from Japan | 125lm±5%( CCT=5000K) | 11250lm±5%(CCT=5000K) | 5000K | 30°x70,60°x90°,120°,,40°x130° | Ra70/Ra80 | 90% | Mean Well | 100~240VAC/100~277VAC | 50~60Hz | 24~48VDC | 1. 9A( Constant Current) | 93% | 0. 93 | 15% | 90±3W | 84±3W | Aluminum Alloy | IP65 | 4.7±0.3kg | 50000Hrs(Ta=30°C@L70) | 75°C(Ta=30°C) | -40 +70 C | -30~+50°C | 15~90%RH | 718×137×102mm | 790×200×160mm |
120W HIRACK LED LINEAR HIGH BAY | Nichia SMD from Japan | 125lm±5%( CCT=5000K) | 15000lm±5%(CCT=5000K) | 5000K | 30°x70,60°x90°,120°,,40°x130° | Ra70/Ra80 | 90% | Mean Well | 100~240VAC/100~277VAC | 50~60Hz | 24~48VDC | 2.6A(Constant Current) | 93% | 0. 93 | 15% | 120±3W | 112±3W | Aluminum Alloy | IP65 | 5.7±0.3kg | 50000Hrs(Ta=30°C@L70) | 75°C(Ta=30°C) | -40 +70 C | -30~+50°C | 15~90%RH | 948×137×102mm | 1020×200×160mm |
150W HIRACK LED LINEAR HIGH BAY | Nichia SMD from Japan | 125lm±5%( CCT=5000K) | 18750lm±5%(CCT=5000K) | 5000K | 30°x70,60°x90°,120°,,40°x130° | Ra70/Ra80 | 90% | Mean Well | 100~240VAC/100~277VAC | 50~60Hz | 24~48VDC | 3.2A(Constant Current) | 93% | 0. 93 | 15% | 150±3W | 140±3W | Aluminum Alloy | IP65 | 6.9±0.3kg | 50000Hrs(Ta=30°C@L70) | 75°C(Ta=30°C) | -40 +70 C | -30~+50°C | 15~90%RH | 1178×137×102mm | 1250×200×160mm |
180W HIRACK LED LINEAR HIGH BAY | Nichia SMD from Japan | 125lm±5%( CCT=5000K) | 22500lm±5%(CCT=5000K) | 5000K | 30°x70,60°x90°,120°,,40°x130° | Ra70/Ra80 | 90% | Mean Well | 100~240VAC/100~277VAC | 50~60Hz | 24~48VDC | 3.8A(Constant Current) | 93% | 0. 93 | 15% | 180±3W | 168±3W | Aluminum Alloy | IP65 | 8.5±0.3kg | 50000Hrs(Ta=30°C@L70) | 75°C(Ta=30°C) | -40 +70 C | -30~+50°C | 15~90%RH | 718×275×102mm | 790×338×160mm |